The Danger of Surgical Display Latency

In the operating room, the term "real-time" is not a marketing buzzword; it is a fundamental requirement for patient safety. Surgeons rely on a seamless visual feedback loop where their hand movements are instantly and accurately reflected on the surgical display. Even a delay that seems imperceptible in other contexts can be devastating during surgery. A one-second lag is an extreme case, but it powerfully illustrates the danger of latency—the delay between an event happening and it being seen. This delay is not a single, simple problem but a cumulative effect of every component in the video chain, from the endoscope’s camera to the display panel itself. Understanding, measuring, and mitigating this latency is one of the most critical challenges in designing modern integrated operating rooms. This article explores the causes and catastrophic clinical risks of display latency1 and outlines a systematic approach to engineering a verifiable, low-latency video ecosystem.

Defining and measuring surgical display latency

To control latency, treat it as an end-to-end phenomenon and measure for both typical and worst-case scenarios across real surgical tasks.

Surgical display latency is the total “glass-to-glass” delay from camera to screen. It must be measured end-to-end, logging typical and worst-case values, including added lag during dynamic events like source switching.

An infographic illustrating the
Measuring Glass-to-Glass Surgical Latency

Surgical display latency2 is the total time it takes for an image to travel from the "glass" of the endoscope or surgical camera lens to the "glass" of the monitor screen. It is a cumulative delay, with milliseconds being added at every step of the video signal chain. Simply looking at the specification sheet for a single component, like the display’s response time, is misleading. A comprehensive measurement must capture the entire journey. This involves specialized equipment that can generate a light signal at the camera source and measure the precise moment it appears on the display.

What to Measure

Track both typical and worst-case latency, because delay is not constant. Capture spikes during common intraoperative events, including:

  • Switching video sources (e.g., endoscope ↔ PACS)
  • Enabling PIP/PBP or other multiview layouts
  • Zooming or applying DSP
  • Starting recording/streaming

Set clear targets and verify under all conditions: glass-to-glass ≤ 50 ms (typical) / ≤ 80 ms (worst-case). Log results in an audit-ready record.

Technical causes of OR video delay

Latency is “death by a thousand cuts”—small delays from many places that add up unless the chain is engineered for determinism.

Common latency drivers include image processing like scaling, signal conversions, network buffering or retransmissions, under-specified hardware, and complex multiview processing stacks without a locked signal policy.

A complex flowchart showing different components in an OR video chain (camera, processor, extender, switch, display) with red warning signs at potential latency-inducing points.
Technical Causes of Video Latency in the OR

Understanding the technical root causes of video delay is essential for designing a low-latency system3. Delay accumulates across the chain, and identifying these sources is the first step toward mitigation. One weak link—display, signal, or environment—breaks the chain.

Processing and Conversion Delays

Non-native scaling and resampling add processing time. Heavy DSP (denoise/sharpen/stabilize) further increases latency. Any conversions (e.g., 8-bit → 10-bit, 4:2:2 ↔ 4:4:4) or frame–refresh mismatches can introduce judder, dropped/repeated frames, and perceived lag.

Transport and Integration Bottlenecks

Video-over-IP/KVM can add variable latency via buffering and retransmits. In wired systems, under-spec switchers, long/weak extenders, or daisy-chained gear degrade signal integrity. Deep multiview compositing stacks add cumulative processing. Unlocked EDID/bit-depth forces renegotiation and mode switches.

Clinical risks of display latency

When the visual loop is delayed, fine motor control and team timing degrade—risk rises even if no single error is “dramatic.”

A lengthened visuomotor loop caused by latency drives instrument overshoot, uneven sutures, and thermal injury from excessive dwell time. This increases complication risks, case duration, and the surgical team’s cognitive load.

An illustration showing a surgeon's view. Their hand has stopped an instrument at a target location, but on the lagging screen, the instrument still appears to be moving, causing them to overshoot the mark.
Clinical Risk of a Lagging Visuomotor Loop

Impaired Motor Control4 and Tissue Damage

Instrument overshoot can cause unintended dissections or punctures. Suturing precision suffers, yielding uneven or insecure stitches. With energy devices, dwell time increases as the surgeon waits for visual confirmation, risking thermal injury.

Increased Cognitive Load and Procedural Time

Persistent compensation for lag exhausts attention and increases late-procedure error propensity. Unpredictable delay during switching/zoom desynchronizes cues among team members, fueling miscommunication. Net effect: higher complication risk and longer cases.

A verifiable low-latency solution

Low latency is engineered—not hoped for—by locking transport, signal policy, layouts, and QA into a single deterministic system.

Engineer determinism with high-bandwidth transport, lock the signal chain to 10-bit 4:4:4 with fixed EDID, use fixed multiview templates, and institutionalize glass-to-glass latency testing with audit logs.

An image of a medical technician using a latency tester on a surgical display, with a checklist nearby confirming the system passes under various conditions (multiview, recording).
Verifying a Low-Latency Surgical Video Solution

Building a Deterministic Pipeline

Use point-to-point, high-bandwidth links: DisplayPort for near-field, 12G-SDI or fiber SDI for distance. Enforce end-to-end 10-bit, 4:4:45 and fixed EDID/bit-depth policies; disable non-essential DSP. Align frame output and display refresh (use genlock if needed). For multiview, avoid ad hoc windows—enforce fixed templates (e.g., Quad-OR-A, PIP-Scope-L, PBP-Scope-Vitals) bound to user profiles.

Room environment: maintain 20–40 lux ambient light with bias lighting; eliminate direct glare and reflections to preserve near-black visibility.

The Role of Institutionalized Testing

Make testing routine: perform glass-to-glass measurements at install and on a periodic schedule, covering single-source, multiview, zoom/DSP, recording/streaming, and source switching. Target ≤ 50 ms typical / ≤ 80 ms worst-case and capture results in auditable logs.

Latency Test Matrix (example template)

Scenario Typical (ms) Worst-case (ms) Pass/Fail Notes
Single source (native)
Multiview (Quad template)
Zoom / DSP active
Recording/Streaming ON
Source switch (A→B)

Recommended Low-Latency Surgical Displays

Model Size/Resolution 10-bit 4:4:4 12G-SDI DP/HDMI Fixed Multiview EDID Lock Notes
MS321PB 31.5" 4K Yes Yes Yes Yes Yes Yes Tower/boom primary display
MS322PB 32" 4K Yes Yes Yes Yes Yes Yes Same class, size preference
MS550P 55" 4K Yes Yes Yes Yes Yes Wall/main team display
MS270P 27" FHD Yes Yes Yes Yes Yes Mobile cart / auxiliary
MS220SA 21.5" FHD Yes Yes Yes Template-ready Yes Basic endoscopy/info

For specs or demo images: info@reshinmonitors.com

Measurable business value

Low-latency, fixed-template systems reduce risk and improve throughput—benefits that are measurable in clinical and operational KPIs.

Low latency reduces errors and shortens case times, while standardized and auditable systems cut rework, simplify maintenance, and lower the total cost of ownership, making deployments more predictable.

A dashboard showing key performance indicators:
Business Value of Low-Latency Surgical Systems

Operational and Financial Gains

Standardizing a deterministic video chain with a consistent BOM and cabling plan simplifies installation, maintenance, and troubleshooting. Audit-ready latency reports streamline acceptance and compliance. Over time, reliability lowers TCO by reducing support overhead and making upgrades predictable.

FAQ

Does a one-second lag always mean there is a network problem?

No. Significant latency can accumulate in wired systems via scaling, heavy DSP, frame-rate mismatches, and cascaded extenders/switchers.
Action: profile each hop; log per-scenario latency into the matrix.

Is using multiview (PIP/PBP) inherently slower?

It depends on implementation. Software compositing can add variable delay; hardware compositors with fixed templates and sufficient bandwidth can make it negligible.
Action: test with your target layout active and record typical/worst-case.

What is an acceptable latency threshold in surgery?

Define it per clinical scenario and institutionalize in SOPs.
Action: run glass-to-glass tests for laparoscopy/arthroscopy, etc., and set ≤ 50 ms typical / ≤ 80 ms worst-case targets with logs.

Can wireless video work in the OR?

Only within a strict latency budget and with a wired fallback.
Action: verify stability under peak-load conditions; document failover behavior and thresholds.

Conclusion

Make "real-time" a measurable, repeatable, and auditable standard through deterministic transport, locked signal chains, fixed templates, and routine QA—then verify it with glass-to-glass ≤ 50 ms typical / ≤ 80 ms worst-case across real OR scenarios. Actual thresholds should align with your clinical SOPs and regulatory guidance. ⚙️

👉 For expert consultation and Reshin’s real-time surgical display solutions, contact info@reshinmonitors.com.


  1. Exploring display latency can reveal its impact on surgical precision and patient care, making it essential for medical professionals. 

  2. Understanding surgical display latency is crucial for optimizing surgical procedures and ensuring real-time image accuracy. 

  3. Exploring low-latency system design can significantly enhance user experience in real-time video applications. 

  4. Understanding the impact of impaired motor control can enhance surgical techniques and patient safety. 

  5. Understanding 10-bit, 4:4:4 is crucial for high-quality video production. Explore this link to learn its benefits and applications. 